Ultimus I
Air input: 5.5–7.0 bar (80–100 psi)
Air output: 0–7.0 bar (0–100 psi)
Ultimus II
Air input: 5.5–7.0 bar (80–100 psi)
Air output: 0–1.0 bar (0–15 psi)
Specifications
NOTE: Specications and technical details are subject to engineering change without prior notication.
Item Specification
Cabinet size 14.3
W x 18.1H x 17.3D cm (5.63W x 7.12H x 6.82D")
Weight 2.3 kg (5.0 lb)
Power adapter AC input: 100–240 VAC (+/-10%), ~50/60Hz, 0.6 Amp
DC output: 24 VDC @ 1.04 Amp
End-of-cycle feedback circuits 5–24 VDC; 100 mA maximum
Initiate circuits Foot pedal, nger switch, or 5–24 VDC signal
Cycle rate Exceeds 600 cycles per minute
Time Range: Programmable from 0.0001–999.9999 seconds
Accuracy: Within ±0.05% of the selected time setting
Repeatability: Less than 16 μsec at any time setting
Pressure readout accuracy Ultimus I: ±2.0 psi, 0–7.0 bar (0–100 psi)
Ultimus II: ±0.3 psi, 0–1.0 bar (0–15 psi)
Vacuum readout accuracy ±2.0 inH
2
O, 0–18 inH
2
O
Ambient operating conditions Temperature: 5–45° C (41–113° F)
Humidity: 85% RH at 30° C non-condensing
Height above sea level: 2000 m maximum (6,562 ft)
Approvals CE, RoHS, WEEE, UL, and China RoHS compliant
Meets or exceeds CE and CSA requirements
120.7 mm
4.75"
180.8 mm
7.12"
143 mm
5.63"
173.2 mm
5.63"
159.5 mm
6.28"
Ultimus I–II High Precision Fluid Dispensers
10 www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.