Barrel Rack
P/N 7022411 for 3cc and 5cc barrels
P/N 7022429 for 10cc, 30cc, and 55cc
barrels
Filling the cartridge for the
Atlas Filling System.
Luer-to-luer tting
P/N 7012606 100 pack
P/N 7014838 1 piece
P/N 7022068 Atlas Filling System
Syringe Barrel Loading Alternatives
Nordson EFD offers productive alternatives to traditional syringe barrel loading methods. Here are a few suggestions
that can help keep your work area clean, save time, and reduce the chance of entrapped air in the uid.
• Use the Atlas
™
Filling System, P/N 7022445 (12 oz). Pack the uid into a 2.5 oz, 6 oz, 12 oz, 20 oz, or
32 oz cartridge as shown. Then place the pre-lled cartridge into the barrel loader. Using air pressure, the barrel
loader lls the syringe barrel (with a piston installed) from the bottom up.
If the uid comes packed in a 300 ml (1/10 gallon) caulking type cartridge, use the EFD P/N 7022452 lling
system.
For fast, volumetric lling, the P/N 7022068 Atlas Filling System is an accurate, easy, and fast system for lling
syringe barrels.
• If you receive frozen epoxies or other uids in medical type syringes with a manual plunger, request the EFD luer-
to-luer tting to transfer the material.
Contact an EFD uid application specialist for additional assistance.
P/N 7022445 (12 oz) Atlas Filling
System. Also available in 2.5, 6, 20,
and 32 oz.
P/N 7022452 for pre-lled 300mL
(1/10 gal) caulking tubes.
Ultimus I–II High Precision Fluid Dispensers
28 www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.