Features & Controls: Back Panel (continued)
Foot Pedal / Finger Switch Port
The switch port, a 6-pin mini DIN connection, is located on the top right corner of the Ultimus. It is used to connect
the foot pedal or nger switch that activates the dispense cycle. Be sure to align the foot pedal or nger switch cord
connector so that arrow on the connector is on top.
Exhaust Port
The exhaust port is the larger 8 mm pneumatic tting located at the bottom left corner of the Ultimus workstation.
If needed, you can connect a cleanroom lter mufer to lter output air to meet Fed 209-B (0.5 micron
particulates). For dispenser accressories, refer to “Accessories” on page 29.
Use EFD lter / mufer P/N 7016875 or wear adequate ear protection when operating the vacuum in close proximity
for a prolonged period of time.
CAUTION
Air Input Port
The air input port is the smaller pneumatic tting (6 mm) located at the bottom right corner of the Ultimus
workstation.
1. Push one end of the 6 mm air input tubing into the air input tting on the back of the Ultimus. A 2.4 mm (8 ft)
length of air tubing is provided.
2. Connect the other end of the air input tubing to your plant air supply. A standard 1/4 NPT tting is included with
your unit.
NOTE: Clean, dry ltered factory air is required to meet warranty. If your air supply is not ltered, order the 5-micron
lter regulator. For dispenser accressories, refer to “Accessories” on page 29.
Bottled nitrogen can be used. If high pressure bottled air or nitrogen is used, a high pressure regulator must be
installed on the bottle and set at 7.0 bar (100 psi) maximum. In this instance, the 5-micron lter regulator is not
required.
WARNING
A pressure regulator of 0–7.0 bar (0–100 psi) is intended to be provided before connecting the unit to the air supply.
CAUTION