(09) 4-Hour Fire † This sensor type is continuously armed
24-hours-a-day. A sensor programmed
to this type will trigger the local alarm re
sounder and the bell output regardless
of the mode the system is in. This sensor
type is typically used for wireless smoke
detectors. This sensor type is always
active and cannot be bypassed.
(10) Interior with
Delay
This sensor type operates as a delayed
sensor when the system is armed in the
Away mode, and when triggered, will start
the Entry Delay 1 timer. If the system
is armed in Away mode with no Entry
Delay (armed instant), this sensor type will
trigger an instant alarm.
If the system is armed in Stay mode (or
Stay mode with no Entry Delay), this
sensor type will be bypassed.
(14) 24-Hour
Carbon Monoxide
This sensor type is continuously armed
24-hours-a-day. A sensor programmed to
this type will trigger the local alarm pulse
sounder and the bell output regardless
of the mode the system is in. This sensor
type is typically used for wireless carbon
monoxide detectors. This sensor type is
always active and cannot be bypassed.
(16) 24-Hour Fire
Veri cation
This sensor type is continuously armed
24-hours-a-day. A sensor programmed to
this type can trigger the local alarm re
sounder and the bell output regardless
of the mode the system is in. This sensor
type is typically used for wireless smoke
detectors. This sensor type is always
active and cannot be bypassed.
For veri cation, this sensor type must
be violated twice in two (2) minutes, or
remain violated for 30 seconds. If any
other re sensor (veri ed sensor type or
not) violates within two (2) minutes, both
sensors will cause a re alarm.
(23) No Response
Type
This sensor type is a special zone that can
be monitored for activity or inactivity by the
Central Station. It does not affect security
system status.
(24) Silent
Burglary
This sensor type is for silent triggering
the burglary alarm with perimeter doors
and windows that will not be used to enter
or exit the protected premises while the
system is armed. The Control Panel’s
sounder and the bell output will not
activate.
An instant silent alarm will occur when this
type of sensor is triggered with the system
armed in either the Stay or Away mode.
† Indicates sensor types that are not allowed for hardwired loops.