Page 8 AFP-2800 - Fire Indicator Panel – System Description
© N
OTIFIER
I
NERTIA
P
TY
L
TD
, 2001
WWW
.
INERTIA
.
COM
.
AU
3.3
3.33.3
3.3 E
EE
E
L
LL
LECTRICAL
ECTRICAL ECTRICAL
ECTRICAL
S
SS
S
PECIFICATIONS
PECIFICATIONSPECIFICATIONS
PECIFICATIONS
3
33
3
3
33
3
.
..
.
.
..
.
3
33
3
3
33
3
.
..
.
.
..
.
1
11
1
1
11
1
P
PP
P
P
PP
P
O
OO
O
O
OO
O
W
WW
W
W
WW
W
E
EE
E
E
EE
E
R
RR
R
R
RR
R
S
SS
S
S
SS
S
U
UU
U
U
UU
U
P
PP
P
P
PP
P
P
PP
P
P
PP
P
L
LL
L
L
LL
L
Y
YY
Y
Y
YY
Y
Parameter PS243 (3Amp Supply) PS249 (9Amp Supply)
Input Voltage 240 V AC +/- 10% 240 V AC +/- 10%
Input Range 216 V AC to 254 V AC 216 V AC to 254 V AC
Output Voltage 24 V DC nom. 24 V DC nom.
27.6 V DC no load 27.6 V DC no load
26.5 V DC full load 26.5 V DC full load
Adjustable Range 12 V DC to 30 V DC 12 V DC to 30 V DC
Rated Current Of Power Supply 3.0A @ 26.5 V DC 9.0A @ 26.5 V DC
Max Device Rating (electronic) 3.5A @ short circuit 9.5A @ short circuit
Overload Current Device 7.4A @ Short Circuit 20A @ Short Circuit
Secondary Transformer Fuse 5 A 15 A
Max Ripple 150 mV p-p 150 mV p-p
Load Regulation 2% 2%
Line Regulation 2% 2%
Temperature Coefficient
0.002V/°C 0.002V/°C
Efficiency >80% >80%
Switching Frequency 200 kHz 200 kHz
Battery Test Internal: 15 ohms Internal: 15 ohms
Battery Test Relay Contact Rating 10A 15A
Indicators Mains On, Output On Mains On, Output On
Status Indicators By External Interface or
FIP
By External Interface or
FIP
Environmental
-10°C to +55°C Dry heat
+40°C @ 93% RH
-10°C to +55°C Dry heat
+40°C @ 93% RH
WARNING: Severe damage will result if the batteries are connected incorrectly.
3
33
3
3
33
3
.
..
.
.
..
.
3
33
3
3
33
3
.
..
.
.
..
.
2
22
2
2
22
2
C
CC
C
C
CC
C
P
PP
P
P
PP
P
U
UU
U
U
UU
U
&
&&
&
&
&&
&
T
TT
T
T
TT
T
E
EE
E
E
EE
E
R
RR
R
R
RR
R
M
MM
M
M
MM
M
I
II
I
I
II
I
N
NN
N
N
NN
N
A
AA
A
A
AA
A
T
TT
T
T
TT
T
I
II
I
I
II
I
O
OO
O
O
OO
O
N
NN
N
N
NN
N
B
BB
B
B
BB
B
O
OO
O
O
OO
O
A
AA
A
A
AA
A
R
RR
R
R
RR
R
D
DD
D
D
DD
D
Supply Input
requirements
20 to 28V DC
55mA max (without CPU board or field loops connected)
210mA max (with CPU board, without field loops connected)
larm Inputs
wo conventional Alarm Zone inputs are provided, detecting
open circuit fault, short circuit fault, alarm, and normal. Each
input is monitored and requires a 4K7 (nom) EOL resistor.
Power Outputs
uxiliary Power Output 20-28V 1A max
24V DC & 5V DC Power to Ring Expander Boards
CPU power supply – 5V DC+/- 5% 3A
larm Outputs
x 1A monitored outputs
x ELV relay contact outputs
Communications Link EIA485 on dual ports
24V DC (nom) 2A Max
Note: Up to 200 field modules may be installed. Additional
auxiliary power supply(s) will be required, depending on the
number of field modules installed.
Indications LED indications on Relay Outputs and Fuses
Panel Expansion
Relays
Expansion for 64 x 1A ELV relay contact outputs via 8 serial
IFS-803 Relay Boards
www.PDF-Zoo.com