Manual of NCH02
- 25 -
Figure3-3. motor parameter configuration page
The parameter item specifically defines show in table 3-2.
No. Mark Definition Range
1 Stepsper
the number of pulses required for every
forward 1mm
100-20000
2 Velocity
Speed: the manual or the axis G code runs
maximum speed. The unit is mm/min
50-20000
3 Accel
Acceleration: the manual or the axis G code
runs the maximum acceleration. The unit is
mm/min2
10-5000
4 Reserved
System reserved, undefined
5 Step level
The pulse level, 0 indicates that the output
level is 0V when no pulse, and the 1 indicates
1/0