3. Measuring run
Run with calibration weight on the right side of the mid centering device
Machines with manual QuickSpan
clamping of the wheel
F 6 Autorun
If Autorun is active (ON) the balancing run is started when the wheel guard is closed. If Autorun is
not active (OFF) the balancing run needs to be started by pushing the START button when the
wheel guard is closed.
F 7 Suppression of minor imbalances / Round off
The suppression and rounding off of the balance results can be selected with this function
The suppression (lin) indicates below which value the imbalance is shown as „Zero“.
The round off (rnd) states in whwat steps the imbalance is displayed.
F 8 Wheel guard
SEC ON If the wheel guard is opened during the measuring run the wheel is stopped to an
immediate standstill
SEC OFF If the wheel guard is opened during the measuring run the motor is switched off and
the wheel runs free. This function is useful to view the run out of the wheel. As soon as the hood
is closed again the measurement run will start again from the beginning
--- The wheel guard switch is put out of operation, the balancing run can be started with the
wheel guard open
This function is only to be used for service purposes

Other manuals for Nussbaum ATT BM Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nussbaum ATT BM Series and is the answer not in the manual?

Nussbaum ATT BM Series Specifications

General IconGeneral
BrandNussbaum
ModelATT BM Series
CategoryWheel Balancers
LanguageEnglish

Related product manuals