SAFETY STOP
Upon ascent to within 5 ft (1.5 m) deeper than the SS (Safety Stop) depth set for 1 second, on a No Decompression dive in which depth exceeded
30 ft (9 m) for 1 second, a beep will sound and a Safety Stop at the depth set will appear on the Dive Main display with a countdown beginning at
the Safety Stop time set and counting down to 0:00.
• If the Safety Stop was set for OFF, the display will not appear.
• In the event that you descend 10 ft (3 m) deeper than the Stop Depth for 10 seconds during the countdown, or the countdown reaches 0:00, the
No Decompression Main screen will replace the Safety Stop Main screen which will reappear upon ascent to within 5 ft (1.5 m) deeper than the
Safety Stop depth set for 1 second.
• In the event that you enter Decompression during the dive, complete the Decompression obligation, then descend below 30 ft (9 m); the Safety
Stop Main will appear again upon ascent to within 5 ft (1.5 m) deeper than the Safety Stop depth set for 1 second.
• If you ascend to 3 ft (0.9 m) of the surface for 1 second, the Safety Stop will be canceled for the remainder of that dive.
• There is no penalty if you surface prior to completing the Safety Stop or choose to ignore it.
LOW BATTERY
WARNING: DO NOT dive with a low battery. Charge the battery before diving if your ProPlus 4.0 indicates the Battery Low
Warning or Alarm.
Warning Level
• The ProPlus 4.0 functions continue but the backlight and Bluetooth are disabled.
• The battery icon appears solid.
Alarm Level
• The ProPlus 4.0 functions continue but the backlight and Bluetooth are disabled.
• When the voltage is below that required for normal operation (< 2.50 volts), the graphics "CHG BATT" shall ash and the Battery icon shall ash
once per second for 5 seconds, then the unit is to shut off.