PO
2
DURING DECOMPRESSION
The PO
2
alarm setting does not apply when in Decompression. If PO
2
exceeds 1.60 while in Decompression, the PO
2
value (= 1.60) will
ash during the audible alarm in place of the Deco Stop/Time. After the audible alarm is silenced, they alternate with Deco Stop/Time
until PO
2
decreases below 1.60.
flashing
HIGH O
2
SAT (OXYGEN SATURATION)
Warning >> at 80 to 99% (240 OTU)
Alarm >> at 100% (300 OTU)
WARNING
When O
2
saturation reaches the Warning Level, the audible alarm sounds and the O2% (oxygen saturation) value will ash in place of
Depth. Depth will be restored when the audible alarm is silenced.
flashing
ALARM
If O
2
saturation reaches the Alarm level, the audible alarm sounds. The UP message, Up Arrow, and the O2% (oxygen saturation) value
will ash in place of Depth and NO DECO (No Decompression). They will alternate after the audible alarm is silenced.
flashing
WARNING DURING DECOMPRESSION
When O
2
saturation reaches the Warning Level, the audible alarm sounds and the O2% (oxygen saturation) value will ash in place of
Depth. When the audible alarm is silenced, current Depth value will be restored.
flashing