46
PROPLUS 4.0 OPERATING MANUAL
© Pelagic, 2019 Doc. No. 12-5669-r01 (1/18/19)
CAN BE USED AS
Dive Computer (Air or Nitrox)
Digital Depth Gauge/Timer
DIVE COMPUTER PERFORMANCE
Buhlmann ZHL-16c based PZ+, or DSAT based, algorithm.
No Decompression limits closely follow PADI RDP.
Decompression in agreement with Buhlmann ZHL-16c and French MN90.
No Decompression Deep Stops - Morroni, Bennett.
Decompression Deep Stops (not recommended) - Blatteau, Gerth, Gutvik.
Altitude - Buhlmann, IANTD, RDP (Cross).
Altitude corrections and O2 limits based on NOAA tables.
OPERATIONAL PERFORMANCE
Function: Accuracy:
Depth ±1% of full scale
Timers 1 second per day
Dive Mode Activation:
Manually by pressing any button or automatic by immersion in water.
Cannot operate as a DC at elevations higher than 14,000 feet (4,270 meters)
Dive Counter:
Norm/Gauge displays Dives #1 to 24.
Resets to Dive #1, upon diving (after 24 hours with no dives).
Dive Log Mode:
Stores max 24 entries per day, 99 entries in memory for viewing.
After 24 dives in one day or 99 dives overall, new dives overwrite older dives.
Altitude:
Operational from sea level to 14,000 feet (4,270 meters) elevation.
Measures ambient pressure every 30 minutes in Watch mode, when Dive Computer mode is accessed, and every 15 minutes while in DC Surface
modes.
Does not measure ambient pressure when wet.
Compensates for Altitudes above sea level beginning at 3,001 feet (916 meters) elevation and every 1,000 feet (305 meters) higher.
Power:
CR2 3V lithium battery
Battery Indicator:
Graphical level gauge
Operating Temperature:
Out of the water - between 20 °F and 140 °F (-6 and 60 °C).
In the water - between 28 °F and 95 °F (-2 and 35 °C).
BAR GRAPHS:
TLBG
• No Deco Normal zone 0-70%
• No Deco Caution zone 71-99%
• Decompression zone 100%
VARI
Normal zone 3 segments
Caution zone 4 segments
Too Fast zone 5 segments
SPECIFICATIONS