EasyManua.ls Logo

OHAUS EB15 - User Manual

OHAUS EB15
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
i
EB Series instruction Manual
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com

Other manuals for OHAUS EB15

Questions and Answers

  • D
    Diana CarrollAug 18, 2025
    Why does my OHAUS EB15 read incorrectly?
    • D
      deanhillAug 18, 2025
      If your OHAUS Scales reads incorrectly, it might need calibration, so perform a Service Calibration as described in Appendix A. Another potential cause is a damaged Load Cell, which you should test and replace if defective, referring to Section 3.3. Lastly, a defective Main PC Board could also be the reason; this should be tested and replaced as per Section 3.4.
  • H
    Hannah MooreAug 20, 2025
    What to do if OHAUS Scales will not turn on with AC adapter?
    • E
      Elizabeth TorresAug 20, 2025
      If your OHAUS Scales will not turn on with the AC adapter, the adapter might be defective. Check the AC adapter's voltage output as described in Section 3.1; if the voltage is low or nonexistent, replace the adapter. Another possibility is a defective Membrane Switch, which should be tested and replaced if necessary, according to Section 3.2. Finally, the Main PC Board could be defective and should be tested and replaced following the instructions in Section 3.4.
  • D
    donna14Aug 23, 2025
    Why OHAUS EB15 Scales can be turned on but will not calibrate?
    • M
      Max HancockAug 23, 2025
      If your OHAUS Scales can be turned on but will not calibrate, verify that you are using the correct weights. A defective Load Cell assembly could also be the cause; test the Load Cell as described in Section 3.3 and replace it if necessary. Additionally, the Main PC Board might be defective and should be tested and replaced according to Section 3.4.
  • G
    Gary FieldsAug 25, 2025
    What to do if OHAUS EB15 display --OL--?
    • D
      Dennis FreyAug 26, 2025
      If your OHAUS Scales display '--OL--', it means the load on the pan exceeds the scale's capacity. To resolve this, reduce the weight on the pan.
  • D
    Daniel McgeeAug 27, 2025
    Why my OHAUS Scales do not display weight accurately?
    • A
      Andrea NelsonAug 28, 2025
      If your OHAUS Scales don't display weight accurately, it might be due to improper calibration. Calibrate the scale using the correct calibration weights to fix this issue.
  • A
    Anthony CollinsAug 30, 2025
    What to do if the weight reading does not stabilize on OHAUS EB15?
    • S
      scottpatriciaAug 30, 2025
      If the weight reading on your OHAUS Scales is unstable, it could be due to an unstable environment. Make sure the scale is placed in a stable location. Another cause might be interference under the pan. Ensure the weighing pan is unobstructed and free to move.
  • A
    Austin CherrySep 1, 2025
    What to do if the display is not on OHAUS EB15?
    • R
      Robert SmithSep 1, 2025
      If the display on your OHAUS Scales is not on or shows partial characters, the Display PC Board or LCD might be defective, so replace the Display PC Board or LCD.
  • J
    Jamie FloresSep 3, 2025
    What does E4 error code mean on OHAUS Scales?
    • M
      Matthew JordanSep 3, 2025
      If your OHAUS Scales display an E4 error code, it could be due to a sample weight that is too small for setting up Counting APW. Increase the weight on the pan until the resulting APW is greater than the minimum. It could also mean the value for setting up Percent weighing is not valid, in which case you should place a reference weight greater than 9d on the pan.
  • K
    Kevin WoodSep 5, 2025
    What does E2 error code mean on OHAUS EB15 Scales?
    • R
      Richard CraneSep 6, 2025
      If your OHAUS Scales display an E2 error code, it indicates that the A/D count is not correct. To resolve this, have the load cell replaced.
  • T
    tony25Sep 8, 2025
    What does E1 error code mean on OHAUS EB15 Scales?
    • H
      holtelizabethSep 8, 2025
      If your OHAUS Scales display an E1 error code, it means there has been an EPROM data loss. The suggested solution is to replace the scale.

Summary

INTRODUCTION

Product Description

Provides a description of the EB Series as an economical, compact bench scale for industrial weighing.

General Features

Lists key features like capacity, resolution, pan material, display type, application modes, and battery life.

Safety Precautions

Details critical safety guidelines for operating the scale correctly and preventing hazards.

INSTALLATION

Unpacking

Instructions to unpack the scale and verify all included components are present.

Installing Components

Guide on attaching the weighing platform and removing the shipping protection screw.

Selecting the Location

Advice on choosing a stable, level environment free from interference for accurate operation.

Leveling the Scale

Procedure for adjusting the leveling feet to ensure the bubble is centered.

Connecting Power

Covers connecting the AC adapter and information on the internal rechargeable battery status and usage.

Initial Calibration

Recommendation to perform span calibration upon first use for accurate weighing.

OVERVIEW OF CONTROLS AND FUNCTIONS

Display Symbols

Identifies and explains the meaning of various symbols shown on the scale's display.

Controls and Functions

Details the function of each button on the scale and how to use basic operations.

OPERATIONS

Switching the Unit On and Off

Instructions for powering the scale on and off, including warm-up recommendations.

Manual Tare

Explains how to set a tare value to exclude the weight of a container.

Zero Operation

How to reset the display to zero using the ZERO button.

Changing Weighing Units

Guide to cycling through and selecting different units of measurement.

Check-Weighing;Counting, Percent Check

Instructions for using the scale's check-weighing, counting, and percent modes.

Sampling, Calculating Average Piece Weight (APW)

Steps for sampling items to calculate the average piece weight for counting applications.

Displaying Count Data in Counting Mode

How to view piece count, APW, and total weight during counting operations.

Accumulation: Weight and Quantity (Count)

Using the M+ key to accumulate multiple weights or counts into memory.

Percent Weighing

Procedure for performing percent weighing by setting a reference weight.

SCALE SETTINGS

Scale Increment

Setting the scale's readability or graduation for displayed values.

Backlight

Configuring the display backlight activation mode (Auto, On, Off).

Zero Tracking Range

Adjusting the range for maintaining the scale's zero reading.

Filtering

Setting the filtering level to affect stabilization time and stability indication.

CALIBRATION

TROUBLESHOOTING

TECHNICAL DATA

LIMITED WARRANTY

OHAUS EB15 Specifications

General IconGeneral
BrandOHAUS
ModelEB15
CategoryScales
LanguageEnglish

Related product manuals