Questions and Answers

  • H
    hernandezcharlesAug 18, 2025
    Why does my OHAUS EB30 Scales read incorrectly?
    • S
      Samantha HartmanAug 18, 2025
      If your OHAUS Scales reads incorrectly, it might need calibration, so perform a Service Calibration as described in Appendix A. Another potential cause is a damaged Load Cell, which you should test and replace if defective, referring to Section 3.3. Lastly, a defective Main PC Board could also be the reason; this should be tested and replaced as per Section 3.4.
  • K
    Kendra RobertsAug 20, 2025
    What to do if OHAUS EB30 Scales will not turn on with AC adapter?
    • J
      Jordan HernandezAug 20, 2025
      If your OHAUS Scales will not turn on with the AC adapter, the adapter might be defective. Check the AC adapter's voltage output as described in Section 3.1; if the voltage is low or nonexistent, replace the adapter. Another possibility is a defective Membrane Switch, which should be tested and replaced if necessary, according to Section 3.2. Finally, the Main PC Board could be defective and should be tested and replaced following the instructions in Section 3.4.
  • A
    Alexis LeeAug 23, 2025
    Why OHAUS Scales can be turned on but will not calibrate?
    • D
      Daniel CamposAug 23, 2025
      If your OHAUS Scales can be turned on but will not calibrate, verify that you are using the correct weights. A defective Load Cell assembly could also be the cause; test the Load Cell as described in Section 3.3 and replace it if necessary. Additionally, the Main PC Board might be defective and should be tested and replaced according to Section 3.4.
  • N
    nathan35Aug 26, 2025
    What to do if OHAUS EB30 display --OL--?
    • L
      Lauren MitchellAug 26, 2025
      If your OHAUS Scales display '--OL--', it means the load on the pan exceeds the scale's capacity. To resolve this, reduce the weight on the pan.
  • J
    jason41Aug 28, 2025
    Why my OHAUS EB30 Scales do not display weight accurately?
    • M
      Mr. Matthew Bridges DDSAug 28, 2025
      If your OHAUS Scales don't display weight accurately, it might be due to improper calibration. Calibrate the scale using the correct calibration weights to fix this issue.
  • E
    Elizabeth OneillAug 30, 2025
    What to do if the weight reading does not stabilize on OHAUS EB30 Scales?
    • J
      Jessica LittleAug 30, 2025
      If the weight reading on your OHAUS Scales is unstable, it could be due to an unstable environment. Make sure the scale is placed in a stable location. Another cause might be interference under the pan. Ensure the weighing pan is unobstructed and free to move.
  • J
    Jeremy WallsSep 1, 2025
    What to do if the display is not on OHAUS EB30 Scales?
    • M
      Mark HortonSep 2, 2025
      If the display on your OHAUS Scales is not on or shows partial characters, the Display PC Board or LCD might be defective, so replace the Display PC Board or LCD.
  • R
    Raymond TerrySep 4, 2025
    What does E4 error code mean on OHAUS Scales?
    • S
      Sherry PerezSep 4, 2025
      If your OHAUS Scales display an E4 error code, it could be due to a sample weight that is too small for setting up Counting APW. Increase the weight on the pan until the resulting APW is greater than the minimum. It could also mean the value for setting up Percent weighing is not valid, in which case you should place a reference weight greater than 9d on the pan.
  • J
    John JohnsonSep 6, 2025
    What does E2 error code mean on OHAUS EB30 Scales?
    • P
      paynehannahSep 6, 2025
      If your OHAUS Scales display an E2 error code, it indicates that the A/D count is not correct. To resolve this, have the load cell replaced.
  • S
    salinasnicholeSep 8, 2025
    What does E1 error code mean on OHAUS Scales?
    • S
      shermanpatriciaSep 8, 2025
      If your OHAUS Scales display an E1 error code, it means there has been an EPROM data loss. The suggested solution is to replace the scale.

Summary

Introduction

Product Description

Concise overview of the EB Series weighing scale's purpose and design.

General Features

Details key capabilities like capacity, resolution, display, and application modes.

Safety Precautions

Essential guidelines for safe and dependable operation of the scale.

Installation

Unpacking

Steps to unpack the scale and verify included components.

Installing Components

Instructions for attaching the weighing platform and securing protective elements.

Selecting the Location

Guidance on choosing an optimal environment for scale operation.

Leveling the Scale

Procedure to ensure the scale is properly leveled using the indicator.

Connecting Power

Details on connecting the scale to AC power and managing battery charging.

Initial Calibration

Instructions for performing the initial span calibration for accurate measurements.

Controls and Functions Overview

Display Symbols

Explanation of icons and indicators shown on the scale's LCD display.

Controls and Functions

Description of the scale's buttons and their respective operations.

Operations

Switching the Unit On and Off

Procedure for powering the scale on and off, including warm-up time.

Manual Tare

How to set and clear a tare value for weighing containers.

Zero Operation

How to zero the scale's display before weighing.

Changing Weighing Units

Procedure to cycle through available units like kg, g, lb, oz.

Check-Weighing;Counting;Percent Check

Using the scale for limit checking, counting items, and percentage weighing.

Sampling and APW Calculation

Steps to sample items and calculate the average piece weight for counting.

Displaying Count Data

How to view Piece Count, APW, and Total Weight in counting mode.

Accumulation of Weight and Quantity

Procedure to add weighed items or counts to memory.

Percent Weighing

How to perform weighing as a percentage of a reference weight.

Scale Settings

Scale Increment

Configures the displayed scale increment (readability or graduation).

Backlight

Sets the activation mode for the display backlight.

Zero Tracking Range

Defines the range for maintaining the zero reading.

Filtering

Adjusts the level for stabilization time and stability indication.

Calibration

Calibration Procedure

Step-by-step guide to calibrate the scale using specified weights.

Troubleshooting

Common Problems and Remedies

Table of common issues, their causes, and suggested solutions.

Technical Data

Specifications by Model

Detailed specifications including capacity, resolution, construction, and dimensions.

Limited Warranty

Warranty Terms and Conditions

Details Ohaus's warranty policy, limitations, and contact information.

OHAUS EB30 Specifications

General IconGeneral
Capacity30 kg
Readability0.01 kg
DisplayLCD
CalibrationExternal Calibration
Units of Measurementkg, g, lb, oz
Tare RangeFull Capacity
Power SupplyAC Adapter
MaterialStainless steel
InterfaceRS232