PAGE 54
© 2015 OJ Electronics A/S
10.4.3 Sensor Application 1/2
This option allows you to choose which sensor is used to control the heating
system.
• Floor: Withthissetting,theoorsensorcontrolstheheatingsystem.
• Room/FloorProtection:Withthissetting,theroomsensorbuiltintothe
thermostat controls the heating system while the floor sensor limits
heating according to the temperature limits set under Menu/Installer
Settings/Floor Protection.
• Room: Withthissetting,theroomsensorbuiltintothethermostatcontrols
the heating system.
Note! Floor Protection is not active while using the Sensor Application
“Room”.
Note that certain menu options will be grayed out and inaccessible as
they are only applicable with the floor sensor.
• Regulator: Withthissetting,thethermostatoperatesasaregulatorandno
sensors are used. The setting is a percentage of the full load in steps
of 10%.
Note that Floor Protection is not active when using the thermostat as
a regulator.
Note: Regulator Mode is not available with SW 1012M101.

Other manuals for OJ Electronics UWG4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the OJ Electronics UWG4 and is the answer not in the manual?

OJ Electronics UWG4 Specifications

General IconGeneral
BrandOJ Electronics
ModelUWG4
CategoryThermostat
LanguageEnglish

Related product manuals