10.4.6 Room Sensor Calibration
This option allows you to calibrate the room sensor.
You can calibrate the sensor if the temperature reading diers from the actual room
temperature.
Note that changes in room sensor characteristics may damage certain floors.
You can calibrate the sensor with ±17°F or ±10°C in steps of 1°F or 0.5°C in the
following way:
1. Tap the “Menu” button on the home screen.
2. Then tap the “Installer Settings” button to access the various installer settings.
3. Tap the “Room Sensor Calibration” button.
4. Use the “Arrow Up” or “Arrow Down” button to set the room temperature
actually measured.
5. Confirm that you want to calibrate the sensor with “” or cancel with “X”.
If the temperature is confirmed with “√”, a confirmation screen will be displayed
briefly.
The thermostat will automatically return to “Installer Settings”.

Other manuals for OJ Electronics UWG4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the OJ Electronics UWG4 and is the answer not in the manual?

OJ Electronics UWG4 Specifications

General IconGeneral
TypeWireless Thermostat
CompatibilityUnderfloor heating systems
Protection ClassIP21
DisplayLCD
MountingWall-mounted
OutputRelay output
Temperature Range5°C to 45°C
Switching Voltage230V AC
Operating Temperature Range0°C to 40°C
Storage Temperature Range-20°C to 60°C
Wireless RangeUp to 30m
Operating modesManual
Dimensions86 x 86 x 20 mm

Related product manuals