64
3.3.11Bail Motor Assy
(1) Remove Cover Assy Access / Cover Assy Side (R) / Cover Assy Side (L) /Cover Assy Front
/ Frame Assy Rear / Plate Front (stuck). (See 3.3.1)
(2) Unplug the connectors 1 from I/F Board (PHA Printed Board)(CN2) B.
(3) Unplug the connectors A from I/F Board (PHA Printed Board)(CN11) B.
(4) Release the cords from the cord clamps on the cord route.
(5) Unscrew the screw 2 and cut the wrapping tie.
(6) Remove Micro Switch 3.
(7) Unscrew 2 screws 4 and remove Bail Motor Assy 5.
(8) Unscrew 2 screws 6 and remove the motor 7.
(9) Remove E rings 8 and 2 gears 9 and 0.
(10)For installation, reverse the removal procedure.
6
0
9
8
2
3
7
4
5
1
B
A
Wrapping tie