D-12
4)
Remove
two
PUK2
x
3.5SO
and
PUK2
x
6SO
on
CA8961
(Frame).
Then
come
off
CA8961
and
the
exposure
meter
mechanism
in
a
unit.
5)
Remove
three
CA9008
(Screw)
to
separate
CA8980
(Pulley)
from
CA8961
(Frame).
The
position
of
the
exposure
meter
mechanism
may
be
adjusted
by
loosening
CA9008
(Screw).
(Coarse
adjustment)
The
position
of
CA8980:
The
groove
of
CA8980
is
to
be
positioned
at
the
shutter
speed
1/1000.
It
should
be
positioned
within
the
range
shown
below
when
CA8879
(Ring)
is
at
the
stopper.
6)
R
emove
three
CA8947
(Screw).
.
Then
will
come
off:
CA8877
(Mount)
CA8888
(Spring)
CA9114
(Screw)
CA8878
(Dial)
CA8947
is
to
be
tightened
from
the
top
in
order.