9-25
Meter Function Menus
9
9.2.17  OT.SC.OF (Output Scale and Offset)
Output scale and offset is used to calibrate your optional analog output to
correspond to the engineering units you desire.
MENU MIN/MAX/
BUTTON MIN/MAX * MENU **
MAIN BUTTON BUTTON
MENU SUB MENU 1 SUB MENU 2 DESCRIPTION
“OT.SC.OF”: OUTPUT SCALE & OFFSET
READ 1 Item #1 of Coordinate #1.
000000. Enter the first value displayed
(“000000.”) by the meter.
OUTPT1 Item #2 of Coordinate #1.
00.0000 Enter first desired
(“04.0000”) output value.
READ 2 Item #1 of Coordinate #2.
000000. Enter the second value 
(“100000.
”) displayed by the meter.
OUTPT2 Item #2 of Coordinate #2.
00.0000 Enter second
(“20.0000”) desired output value.
* The ‘MIN’ button allows you to sequence through “READ 1”, “OUTPT1”,
“READ 2”, and “OUTPT2” headings.
The ‘MAX’ button sends you to the value corresponding to “READ 1”,
“OUTPT1”, “READ 2”, and “OUTPT2” so you can change it (go to the SUB
MENU 2 item).
** The ‘MIN’ button allows you to step through the digits of the applicable
number being changed.
The ‘MAX’ button changes the value of the digit to be displayed.
The ‘MENU’ button stores the selected values for each input required in
“OT.SC.OF”. After the last value (“READ 2”) has been entered and the
‘MENU’ button is pressed, the meter display will advance to “BAUD”.
Every underlined item is the factory preset value.