3.1  SAFETY CONSIDERATIONS
This device is marked with the international caution symbol.   It is important to read
this manual before  installing  or commissioning this  device  as it contains  important
information relating to Safety and EMC
(Electromagnetic Compatibility).
Unpacking & Inspection
Unpack  the  instrument  and  inspect  for obvious shipping damage. Do not attempt to
operate the unit if damage is found.
This  instrument  is  a  panel  mount  device protected  in  accordance  with  Class  I  of  EN
61010 (115/230 AC power connections), Class III for the DC power option (10-32Vdc).
Installation of this instrument should be done by Qualified personnel. In order to ensure
safe operation, the following instructions should be followed.
This instrument has no power-on switch. An external switch or circuit-breaker shall be included
in the building installation as a disconnecting device.  It shall be marked to indicate this function,
and it shall be in close proximity to the equipment within easy reach of the operator. The switch or
circuit-breaker  shall not interrupt the  Protective  Conductor  (Earth  wire),  and  it  shall meet the
relevant  requirements  of  IEC 947–1  and  IEC  947-3  (International  Electrotechnical  Commission).
The switch shall not be incorporated in the mains supply cord.
Furthermore,  to  provide  protection  against  excessive  energy being  drawn  from  the
mains supply in case of a fault in the equipment, an overcurrent protection device shall
be installed.
• The Protective Conductor must be connected for safety reasons. Check that the 
power cable has the proper Earth wire, and it is properly connected. It is not safe
to operate this unit without the Protective Conductor Terminal connected. 
Conductor Terminal connected.
• Do not exceed voltage rating on the label located on the top of the instrument 
housing.
• Always disconnect power before changing signal and power connections.
• Do not use this instrument on a work bench without its case for safety reasons.
• Do not operate this instrument in flammable or explosive atmospheres.
• Do not expose this instrument to rain or moisture.
• Unit mounting should allow for adequate ventilation to ensure instrument does 
not exceed operating temperature rating.
• Use electrical wires with adequate size to handle mechanical strain and power 
requirements. Install without exposing bare wire outside the connector to 
minimize electrical shock hazards.
EMC Considerations
• Whenever EMC is an issue, always use shielded cables.
• Never run signal and power wires in the same conduit.
• Use signal wire connections with twisted-pair cables.
• Install Ferrite Bead(s) on signal wires close to the instrument if EMC problems 
persist.
Failure to follow all instructions and warnings may result in injury!