14
Relay Options
14-1
14.1  FEATURES OVERVIEW
The Dual Relay Output Board and 4 Relay Output Board provides two
isolated (354 V per IEC spacing, 500 test), 7-ampere Form-C
electro-mechanical relays that enable setpoint-triggered switching to an
external device (plus two 1-ampere Form-C electro-mechanical relays for 4
Relay Option). Each relay can accommodate a single setpoint. 200 W,
2500pf snubbers are provided for each normally open contact.
These options may not be used with parallel BCD Board Option. Figure 14-1
and 14-2 shows the board connections and jumper locations.
Figure 14-1 Dual Relay
TABLE 14.1 Dual Relay Board Jumpers
JUMPER FUNCTION
S1A* Drives Relay 1 from SP3 (P6)
S1B not used 
S1C Drives Relay 2 from SP2 (P7)
S1D Drives Relay 1 from SP1 (P6)
S1E* Drives Relay 2 from SP4 (P7)
* Factory preset jumper locations