EasyManua.ls Logo

Omega DP41-S - Digit at a Time Card Address; Figure 13-3 Address Programming Chart for 4 -Line Address

Omega DP41-S
175 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
BCD Option
13-5
13.10 6 DIGIT AT A TIME CARD ADDRESS
Jumpers S2A and S4A are removed for full parallel (6-digit output).
If jumper S3A is installed, the outputs are enabled by line P8-L20 ALONE: a
low level enables the outputs when jumper S5C is installed, and a high or
open level does the job if S5C is removed.
When jumper S3A is removed, the outputs are enabled only when the
selected 4-line address is applied to P8-U19, L19, U20 and L20. Each of
these four is exclusive-OR’d with its jumper, and the following four outputs
are AND’d to create a 1 of 16 enable code.
If jumper S5A is installed, P8-U20 must be LOW to enable the card (BIT 2).
If jumper S5C is installed, P8-L20 must be LOW to enable the card (BIT 1).
If jumper S5E is installed, P8-U19 must be LOW to enable the card (BIT 8).
If jumper S5G is installed, P8-L19 must be LOW to complete enabling the
card outputs (BIT 4).
Figure 13-3. Address Programming Chart for 4 -line Address
NOTE: “X” in chart indicates jumper that must be installed.
EXAMPLE: For a positive true address of 03, install jumpers S5-G and
S5-E.
If any of these jumpers are removed, the corresponding line must go HIGH
or OPEN to assist the card enable; if all four jumpers are missing, for
example, the card outputs are enabled ONLY when all four lines are HIGH or
OPEN, a ground on any of the four input lines causes the outputs to go the
high impedance state.