9-29
Meter Function Menus
9
MENU MIN/MAX/MENU *
BUTTON BUTTON
MAIN MENU SUB MENU DESCRIPTION
“DAT FT”: DATA FORMAT
Alarms 1 & 2 Status Character:
“DAT
.1=0” Excluded
“DAT.1=1” Included
HI/LO (Peak/Valley) Status Character:
“DA
T.2=0” Excluded
“DAT.2=1” Included
Filtered Value to be transmitted:
“DAT.3=0” No
“DAT.3=1”Yes
Filtered value to be
transmitted:
“DAT.4=0”No
“DAT.4=1” Yes
Peak value to be transmitted:
“DAT.5=0”No
“DAT.5=1” Yes
Valley value to be transmitted:
“DAT.6=0”No
“DAT.6=1” Yes
Separator for above items:
“DA
T.7=0” Space
“DAT.7=1” <CR>
Unit of measurement to be transmitted:
“DAT.8=0”No
“DAT.8=1” Yes
* The ‘MIN’ button allows you to sequence through DAT.1, DAT.2, DAT.3,
DAT.4, DAT.5, DAT.6, DAT.7, and DAT.8.
The ‘MAX’ button allows you to select the “0” or “1” state for each “DAT”
condition.
The ‘MENU’ button stores the selected values for each “DAT” condition
changed and advances the meter to the next configuration (“BUS FT”).
Every underlined “0” or “1” is the factory preset value.