EasyManua.ls Logo

Omron 3G3RX2 Series - Page 126

Omron 3G3RX2 Series
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 DriveProgramming Commands
6 - 30
DriveProgramming User’s Manual (I622-E1)
Example
And (Logical AND)
Command Description Argument
Logical AND on <value 1> and <value 2> in
binary format
and (Logical AND)
Result: any variable
Value 1: any variable or constant
(range 128 to 127)
Value 2: any variable or constant
(range 2,147,483,648 to 2,147,483,647)
Format
Flowchart method Text language method
<result> : = <value 1> and <value 2>
Note If an overflow or underflow occurs, the DriveProgramming detects it as an error. Take neces-
sary measures in the application so that they do not occur.
Flowchart Text
Block number
Operation
1 Assigns 6 to U(02).
2 Assigns 12 to U(03).
3 Assigns 4 (binary: 00000100), which is the result of logical AND on 6 (U(02) binary: 00000110) and
12 (U(03) binary: 00001100), to U(04).
4 Jumps to the block 3: loop_ unconditionally.
Value 1 Value 2 Result
000
010
100
111
<result> : = <value 1> and <value 2>

Table of Contents

Other manuals for Omron 3G3RX2 Series

Related product manuals