6 DriveProgramming Commands
6 - 32
DriveProgramming User’s Manual (I622-E1)
Example
XOr (Logical exclusive OR)
Command Description Argument
Logical exclusive OR on <value 1> and <value
2> in binary format.
XOr (Logical exclusive OR)
Result: any variable
Value 1: any variable or constant
(range 128 to 127)
Value 2: any variable or constant
(range 2,147,483,648 to 2,147,483,647)
Format
Flowchart method Text language method
<result>: = <value 1> xor <value 2>
Note If an overflow or underflow occurs, the DriveProgramming detects it as an error. Take neces-
sary measures in the application so that they do not occur.
Flowchart Text
Block number
Operation
1 Assigns 6 to U(02).
2 Assigns 12 to U(03).
3 Assigns 10 (binary: 00001010), which is the result of logical exclusive OR on 6 (U(02) binary:
00000110) and 12 (U(03) binary: 00001100), to U(04).
4 Jumps to the block 3: loop_ unconditionally.
Value 1 Value 2 Result
000
011
101
110
<result> : = <value 1> xor <value 2>