13-29
13 Troubleshooting
CJ-series EtherNet/IP Units Operation Manual for NJ-series CPU Unit (W495)
13-4 Error Log
13
13-4-2 Error Log Error Codes
03C3 FINS/UDP packet discarded 00 hex 01 to FE hex:
Source node address
No
03C4 Server connection error 00 hex: DNS
03 hex: SNTP
04 hex: FTP
06 hex: BOOTP
07 hex: SNMP
08 hex: SNMP Trap
01 hex: Specified host
does not exist
02 hex: No such service at
specified host
03 hex: Timeout
06 hex: Host name resolu-
tion error
07 hex: Transmission error
08 hex: Reception error
09 hex: Other error
0A hex: Obtaining IP
address error
No
03C6 Clock write error 0001: The clock time
could not be updated
because a error occurred
in the CPU Unit.
Clear the error from the
CPU Unit.
No
0002: The clock time
could not be updated
because the CPU Unit or
operating mode does not
support this function.
Refer to Section 12 Com-
munications Performance
and Communications
Load and check the appli-
cation conditions.
03D0 Ethernet basic setting error 01 hex: Ethernet setting
error
01 hex: Checksum error
11 hex: Inconsistent set-
tings
12 hex: Specified baud
rate is not supported.
Ye s
02 hex: TCP/IP basic set-
ting error
01 hex: Checksum error
11 hex: Invalid IP address
12 hex: Invalid subnet
mask
13 hex: Invalid default
gateway address
14 hex: Invalid primary
name server
15 hex: Invalid secondary
name server
16 hex: Invalid domain
name
17 hex: Invalid host name
Error
code
(hex)
Error
Detail code Saved in
non-volatile
memory
First byte Second byte