1-6SectionPreparation for Operation
27
4. Initial Settings
Turn OFF the CPU Unit’s Communications Switch, if necessary.
(When this switch is OFF, communications with devices other than the
Programming Console are governed by the settings in the PC Setup.)
Connect the Programming Console, set the mode switch to PROGRAM
mode, and turn ON the PC.
Check the CPU Unit’s LED indicators and the Programming Console’s dis-
play.
Clear the PC’s memory. (All Clear)
Make PC Setup settings.
Refer to 3-3 Installing the CPM2A for details.
5. Create Ladder Program
Create a ladder program to control the system.
Refer to the Programming Manual for details.
6. Write Ladder Program in PC
Write the ladder program in the PC with the Programming Console or
transfer the program to the PC from the Support Software.
Refer to Section 4 Using Programming Devices, to the SYSMAC Support
Software Operation Manuals and to the CPT User Manual for details.
7. Test Run
Check I/O wiring in PROGRAM mode.
Check and debug program execution in MONITOR mode.
Refer to Section 5 Test Runs and Error Processing for details.