Loading...
9
I/O Configuration and Main Functions Section 1-2
E5AN/EN
Note Functions can be assigned individually to each output by changing the set val-
ues for the Control Output 1 Assignment, Control Output 2 Assignment, Auxil-
iary Output 1 Assignment, Auxiliary Output 2 Assignment, and Auxiliary
Output 3 Assignment parameters in the advanced function setting level.
Temperature input
or analog input
Control
section
CT1 input
CT2 input
Event inputs 1 and
2 (2 channels)
Control output
(heating)
Control output
(cooling)
Alarm 3
Alarm 1
Alarm 2
HB alarm
HS alarm
Input error
Program end
output
Communications
function
Heating/cooling
Control output 1
Control output 2
Alarm output 1
Alarm output 2
Alarm output 3
External power
supply for ES1B
OC alarm
(See note.)
(See note.)
Note:
Press one of these keys,
depending on the model.