I - 2
E5@C Digital Temperature Controllers User’s Manual (H174)
Numerics
2-PID control ......................................................4-14, 6-45
A
AD Converter Error ......................................................A-16
Adjustment Level ............................................... 6-18, A-26
Advanced Function Setting Level ...................... 6-61, A-32
air cooling/water cooling tuning ..................................... 5-9
alarm delays ................................................................ 5-26
alarm hysteresis .......................................................... 4-38
alarm latches ............................................................... 4-39
alarm operation ........................................................... 4-39
alarm outputs ............................................................... 4-32
alarm types .................................................................. 4-32
alarm values ................................................................ 4-35
alarms .......................................................................... 4-17
alarms (standard alarms) .............................................. 1-3
analog inputs ..........................................................5-5, 7-9
assigning outputs ........................................................ 4-16
AT (auto-tuning) .......................................................... 4-24
auto/manual control ..................................................... 5-13
auto-tuning (AT) .................................................4-24, 6-20
auxiliary output opening and closing in alarm ............. 4-19
auxiliary outputs 1 to 4 ................................................ 2-65
C
calibrating a current input .............................................. 7-9
calibrating a voltage input ............................................ 7-11
calibrating inputs ........................................................... 7-2
calibrating the transfer output ...................................... 7-13
characteristics ...............................................................A-4
checking indication accuracy ....................................... 7-15
analog input ........................................................... 7-17
infrared temperature sensor .................................. 7-15
resistance thermometer ......................................... 7-16
clearing the program end status .................................. 5-45
cold junction compensator ........................................... 7-15
communications .......................................................... 2-71
communications operation command .......................... 5-21
Communications Setting Level .......................... 6-96, A-38
component communications ....................... 1-4, 6-96, A-38
CompoWay/F .................................................... 6-96, A-38
connecting the cold junction compensator .................... 7-5
control outputs ......................................................1-3, 4-18
control outputs 1 and 2 ................................................ 2-62
control periods ............................................................. 4-15
control ranges ..............................................................A-43
controlling the start of the simple program function ..... 5-13
CT
dimensions ............................................................A-10
E54-CT1 ........................................................A-10
E54-CT3 ........................................................A-11
E54-CT3/CT3L ..............................................A-11
specifications .........................................................A-10
CT inputs ..................................................................... 2-69
current transformer (CT) .................................... 4-44, A-10
Current Value Exceeds ...............................................A-17
D
dedicated protocol (format 4) ............................ 6-96, A-38
derivative time ............................................................. 4-31
detection current values ..............................................4-46
Digit Shift Key ................................................................ 3-9
dimensions .................................................................... 2-2
direct and reverse operation ........................................4-15
Display Range Exceeded ............................................A-16
displaying changed parameters ..................................5-22
Down Key (D Key) ....................................................... 3-7
E
End Plate installation ...................................................2-13
error displays ...............................................................A-15
event inputs .................................................1-4, 2-66, 5-11
extraction of square roots ............................................5-51
F
front panel .....................................................................3-4
E5AC ....................................................................... 3-5
E5CC/E5CC-U/E5CC-B ...........................................3-4
E5DC/E5DC-B ......................................................... 3-5
E5EC/E5EC-B .........................................................3-4
E5GC ....................................................................... 3-6
H
HB alarm ....................................................4-40, A-3, A-17
heater burnout alarm ........................................... 6-65, A-3
heater short alarm ............................................... 4-40, A-3
heating/cooling control .........................................5-7, 6-46
HS alarm ....................................................4-42, A-3, A-17
HS alarms ......................................................................1-3
I
I/O configuration ............................................................1-5
model number legend ............................................1-10
indication ranges .........................................................A-43
infrared temperature sensor ........................................ 7-15
initial setting example
example 1 ................................................................4-8
example 2 ................................................................4-9
initial setting examples ..................................................4-8
Initial Setting Level ..................................... 3-4, 6-41, A-28
initialization .........................................................5-75, 6-63
Input Error ...................................................................A-15
input error .................................................................... 6-33
input sensor types ......................................................... 1-3
input type .....................................................................4-11
inputs ........................................................................... 2-61

Table of Contents

Other manuals for Omron E5EC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron E5EC and is the answer not in the manual?

Omron E5EC Specifications

General IconGeneral
Mounting TypePanel Mount
Display Resolution0.1°C or 1°C
Control MethodON/OFF
Input TypeThermocouple, RTD, Analog voltage
Supply Voltage100 to 240 VAC
Output TypeRelay, Voltage, Current
Size48 x 96 mm
Control OutputRelay, Voltage, Current
Alarm OutputRelay
CommunicationRS-485
Ambient Operating Temperature-10 to 55°C
Ambient Operating Humidity25 to 85% RH
Protection RatingIP20