E5GN
E5GN
INPUT RANGES
Platinum Resistance Thermometer Input/Thermocouple Input
Temperature range
1800
1700
1600
1500
1400
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
0
--100
--200
Pt100 JPt100
Input type
Platinum resistance thermometer input
Platinum resistance thermometer
Name
850
Set value
123 4
--200
500.0
--199.9
100.0
0.0
500.0
--199.9
100.0
0.0
0
Shaded ranges indicate default settings.
Thermocouple
Thermocouple input
ES1A Non-contact
Temperature Sensor
Analog input
Usable in the following
ranges by scaling:
--19999 to 9999 or
--199.9 to 999.9
0to50mV
Temperature range
1800
1700
1600
1500
1400
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
0
--100
--200
Input type
Name K J TELUNRSB
K10 to
70
°
C
K60 to
120
°
C
K115 to
165
°
C
K160 to
260
°
C
Set value
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
--200
500.0
--20.0
1300
850
--100
400.0
--20.0
400
--200
600
0
850
--100
400
--200
1300
--200
1700
0
1700
0
1800
100
70
0
120
0
165
0
260
0
0
Thermocouple Input
Shaded ranges indicate default settings.
Applicable standards by input type are as follows:
K, J, T, E, N, R, S, B: JIS C1602-1995
L: Fe-CuNi, DIN 43710-1985
U: Cu-CuNi, DIN 43710-1985
JPt100: JIS C1604-1989, JIS C1606-1989
Pt100: JIS C1604-1997, IEC751
Note: The ES1A Non-contact Temperature Sensor will be available soon.