EasyManua.ls Logo

Omron J1000 - System Configuration Manual

Omron J1000
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1J1000
JZ
J1000
The basic inverter
• V/f controlled inverter
• Good torque performance (150% / 3 Hz)
• Double rating ND 120%/1min and HD 150%/1 min
• Overload detection function (150% during 60s)
• Motor thermal function
• Freely configurable V/f curve
• 5 programmable digital input
• 1 programmable digital output
• 1 programmable analog output
• Optional RS-232C/485 communication - Modbus,
• CE, UL, cUL and TUV, RoHS
Ratings
• 200 V Class single-phase 0.1 to 1.5 kW
• 200 V Class three-phase 0.1 to 4.0 kW
• 400 V Class three-phase 0.2 to 4.0 kW
System configuration
Copy
V
erify
Read
L
O
C
K
Y
A
S
K
AW
A
J
V
O
P
-
1
8
1
U
S
B
C
o
p
y
U
n
i
t
C
O
M
E
R
R
MCCB
J1000
Filter
AC Reactor
Motor
Ground
Power
Supply
Braking Resistor
DC Reactor
Mounting Accesories
Choke
LED Remote
Operator
Remote Operator
Extansion Cable
RS232 Communications cable with PC
Communication Unit
RJ-45 / USB
Adapter
USB Cable
CX-Drive
CX-One