84 LDî ±Platform Peripherals Guide 13732-000 Rev J
5.7 î ±Specifications
VCC
GND
DIN_1-
DIN_2-
R
R
5
7
V5
R
0.10A
6
8
&
A
B
C
D
Figure 5-30 Input Circuit Schematic
Key Meaning Key Meaning
A Digital Input Circuit C DOOR_IN1
B SAFE_5V D DOOR_IN2
Outputs
l
NO relay with voltage-free contacts
l
Contact rating 30 VDC, 2 A max (resistive)
l
Supports 2 inputs and 2 outputs
These have preset behavior for call buttons, which cannot be changed. The outputs can
be used for a beeper, light, or other use. Both inputs act as external push-button presses.
NOTE: A call button can be turned into a door box with the DIP switch,
in which case the I/O can be configured by the user.
When used as a door box, Output1 is dedicated as a signal to the door actuator to open
the door. Only Output2 is available to the user.
Output1 Output2 Input1 Input2
Call Button ON when
In Progress
ON for ≥ 1 second
after Arrival
Button
press
Button
Press
Door Box Door user user user
I/OBox user user user user
l
Inputs and outputs are configured in the MobilePlanner software.
See Configuring External I/O on page 76 and Configuring an Output Signal on page 74.