96 LDî ±Platform Peripherals Guide 13732-000 Rev J
6.3 î ±Installation
3x M3 x 4
A
B
C
Figure 6-7 Attaching Camera to Camera Bracket, (A) Button Head Cap Screws, (B) Camera
Mounting Bracket, and (C) Camera (units are mm)
Camera Connections
The camera requires a power cable and an Ethernet cable connected to the platform
core. These will pass through the center (17 mm) hole in the camera enclosure base and
bracket.
IMPORTANT: The Acuity camera's signal cabling is sensitive to inter-
ference from noise and its power supply is sensitive to ripple. Route sig-
nal cables to avoid interference. If your payload's power demand is high,
or you need to add other devices to the AUX power circuit, carefully test
Acuity operation before deploying and contact your local Omron Support
if you have problems.
a.
Feed the Hirose end of the power cable and one end of the Ethernet cable up
through the 17 mm hole in the center of the base and bracket, from inside your
payload structure.
b.
Connect the Hirose end of the power cable to the camera.