EasyManua.ls Logo

Omron LD-90 - Page 95

Omron LD-90
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 6: Acuity Localization
R5.1 (0.20)
23.6 (0.93)
5.1 (0.20)
6x R1.5
(0.06)
26.7 (1.05)
33 (1.30)
0
8.4
(0.33)
72.1
(2.84)
2x 91.7
(3.61)
103.6
(4.08)
0
9.9
(0.39)
R5.1 (0.20)
0
5.8 (0.23)
91.7
(3.61)
103.6
(4.08)
0
16
(0.63)
30.5
(1.20)
Ø 42.9
(1.69)
16 (0.63)
Ø 17 (0.67)
3x Ø 5.3 (0.21)
90° on Ø 31 (1.220)
C
L
5.1 (0.20)
10 (0.394)
5.1 (0.20)
9.9
(0.39)
A
B
B
C
Figure 6-6 Dimensional Drawing of Camera Bracket, (A) Through Holes Equally Spaced at,
(B) Through Hole, and (C) Label on Back (units are mm (inches))
3.
Attach the camera to the camera bracket.
a.
Attach the camera cables to the camera before mounting the camera.
Refer to Camera Connections on page 96.
b.
Attach the camera to the mounting bracket using three M3 x 4 mm button head
screws.
NOTE: The camera needs to be mounted as high in the bracket as
possible, without its lens adapter interfering with the ND filter.
This prevents the tube itself from limiting the camera’s angle of
view.
13732-000 Rev J LDî ±Platform Peripherals Guide 95

Table of Contents

Other manuals for Omron LD-90

Related product manuals