18
- Add Devices
In this project file, it is necessary to register the safety CPU to be monitored. There are two
methods: adding as an external device and as an internal device. NA can monitor multiple safety
CPU units. The maximum number of registrable units is 16, including controllers to which the safety
CPU is not connected.
4-3-1 Add External Devices
This section describes how to add devices to another project.
If there is no need to communicate between a CPU unit and NA except monitoring a safety PLC,
such as demonstrations, you don't have to set the IP address to add a safety CPU unit. This is a
recommended method.
1. Right-click [Config/Setting]
[Device Reference]. Then
Left-click [Add] [External
Device].
2. ExternalDevice0 is added.
Double-click it.
3. Click [Device] and select
NX-CSG320.
Note: NX102, NX7, and NJ are
also selectable.
4. Enter the IP address.
Now you have added the safety
CPU unit that you want to
connect.

Other manuals for Omron NA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NA Series and is the answer not in the manual?

Omron NA Series Specifications

General IconGeneral
Touch PanelResistive
InterfacesUSB, Ethernet, RS-232/422/485
Operating Temperature0°C to 50°C
Power Supply24 VDC
Protection RatingIP65 (front panel)
Storage Temperature-20°C to 60°C
Display TypeTFT LCD
DimensionsVaries depending on the model
WeightVaries depending on the model