Programmable Terminal
NA-series
Soft-NA
User’s Manual
V126-E1-01
NA-RTLD

Table of Contents

Other manuals for Omron Sysmac NA Series

Questions and Answers

  • J
    jthomasAug 5, 2025
    What to do if an error occurred and my Omron Monitor does not start up?
    • A
      Alicia LarsonAug 6, 2025
      If an error occurred and the Ladder Monitor does not start up, there could be several reasons. First, the ladder program might not have been transferred; in this case, add a check to the ladder program and then download again. Second, the controller model might not match that set in the project settings; correct the controller model and then download again. Third, the SD Memory Card might not be accessible; check whether or not the SD Memory Card is mounted, ensure that the SD card allows reading and writing to be performed normally using a PC or other device, and use an SD Memory Card recommended by OMRON.
  • M
    mvalentineAug 12, 2025
    Why is the power flow not displayed on my Omron Monitor?
    • N
      nicolebrooksAug 12, 2025
      If the power flow is not displayed on your Omron Monitor, it could be due to several reasons. First, there might be a communications error; in this case, check the connections between the HMI and the controller. Second, the variable information might be being acquired, so wait until the acquisition is complete. Third, an unsupported variable might be assigned to the circuit. Finally, there may be differences between the ladder programs of the HMI and controller; update the data in the project to the latest state and then download the ladder program to the HMI.
  • M
    Matthew TaylorAug 19, 2025
    Why is the header flashing in red on my Omron Monitor?
    • B
      Brandi CardenasAug 20, 2025
      If an error occurred and the header is flashing in red on your Omron Monitor, it means that there are differences between the ladder programs of the HMI and controller. To fix this, update the data in the project to the latest state and then download the ladder program to the HMI.
  • A
    Angie ByrdAug 27, 2025
    Why is the startup of my Omron Monitor so slow?
    • K
      Katie KaneAug 27, 2025
      If the startup of your Omron Monitor is slow, it could be due to the ladder program being huge. The time required to start the Ladder Monitor is influenced by the size of the ladder program, so design the system in consideration of the startup time. Alternatively, the controller might not be started; in this case, start the controller.

Summary

Introduction to the Soft-NA

Soft-NA Overview

Provides an overview of the Soft-NA software, its purpose, and benefits.

System Requirements

Details the hardware and software prerequisites for using the Soft-NA.

Differences from NA-series Terminals

Highlights key distinctions between Soft-NA and traditional NA-series terminals.

Installation and Uninstallation

Installation Method

Step-by-step guide for installing the Soft-NA software.

Uninstallation Method

Instructions for removing the Soft-NA software from the system.

Soft-NA Startup and Exit

Starting the Soft-NA

Procedures for launching and beginning operation with the Soft-NA.

Exiting the Soft-NA

Methods for properly closing and shutting down the Soft-NA application.

Project Management

Creating a Project

Guides on how to initiate and set up new projects for the Soft-NA.

Transferring the Project

Explains the process of moving projects between the PC and the Soft-NA.

Sysmac Studio Functionalities

HMI and Communication Settings

Details configuration options within Sysmac Studio for HMI and network setup.

Clock, Reset, and IAGs

Covers system clock, device resetting, and IAG usage restrictions.

Soft-NA Functionalities

Core Features Overview

Describes function keys, media player, document viewer, and fonts.

System Menu Management

Covers accessing and configuring various system menu settings like language, display, storage, and interface.

Transfer Operations

Covers downloading and uploading projects to/from the HMI.

Error Handling and Troubleshooting

Operation After Error

General procedures to follow when errors occur within the Soft-NA.

Startup and Connection Issues

Solves problems related to Soft-NA startup and Sysmac Studio connectivity.

Runtime Error Resolution

Provides solutions for various runtime errors and output messages.

Appendices and Index

Appendices

Contains differences between Soft-NA and simulator, and version upgrade history.

Index

Alphabetical listing of topics and their page numbers for quick reference.

Omron Sysmac NA Series Specifications

General IconGeneral
Display TypeTFT LCD
Power Supply24 VDC
SoftwareSysmac Studio
Touch TypeResistive
Operating SystemWindows Embedded Compact 7
ConnectivityEthernet, USB, Serial
IP RatingIP65
ProcessorIntel Atom
Brightness400 cd/m²
Viewing Angle160°
Backlight Life50, 000 hours
Operating Temperature0°C to 50°C
Storage Temperature-20°C to 60°C
Humidity10% to 90% (non-condensing)
Vibration Resistance10 to 57 Hz, 0.075 mm amplitude
Shock Resistance147 m/s²