Using NTXS Software
53
Default System Tags
1. System Registers
Tags Tag Name Read / Write Description
S0001 Language Read / Write Writing the value will change languages
used in any wizard
S0003_14 Comm1 status Read Only 0 = Communication Error
1 = Communicating with PLC
S0003_15 Comm2 status Read Only 0 = Communication Error
1 = Communicating with PLC full status
S0004 Number of Historical Read Only Shows number of alarms stored in
memory Alarms
S0005 Screen Trigger Read / Write Shows active screen no. User can
change Register screen by writing any
valid screen no in this register
S0007 Battery Voltage Read Only Indicates battery voltage in #.# format
S0008 Error code for Read only Error code byte for Xtradrive for Com1
Xtradrive Com1
S0009 Error code for Read only Error code byte for Xtradrive for Com2
Xtradrive Com2
2. System Bits
Tags Tag Name Read / Write Description
s0009 Beeper On /Off Read / Write 0: Enable Beeper
1: Disable Beeper
User can change this bit at Run time.
s0010 Battery Status Read only 0: Battery voltage is OK (i.e.above 2.2 V)
1: Low Battery (i.e. below 2.2V)
s0011 Start / Stop jog Read / Write Used in jog operation of Xtradrive for port1
for Xtradrive Com1
1: Continuous jog operation on port1
0: Stop jog operation on port1
s0013 Start / Stop jog Read / Write Used in jog operation of Xtradrive for port2
for Xtradrive Com2
1: Continuous jog operation on port2
0: Stop jog operation on port2