4-132
Operation Procedure
PR02W
operation
Front panel
key operation
Display Explanation
Press the MODE/SET Key to change to System Check
Mode. If a function code other than Fn000 is displayed,
press the Up or Down Key to set function code Fn000.
(See note 1.)
(1 s min.)
Press the DATA Key (front panel: DATA Key for 1 s
min.). The last alarm will be displayed.
Press the Up Key to display the alarm before the alarm
currently displayed. (See note 2.)
Press the Up Key to display the alarms in order of
occurrence. (See note 3).
(1 s min.)
Press DATA Key (front panel: DATA Key for 1 s min.) to
end displaying the alarm history and return to the
function code display.
Note 1. The digits you can manipulate will flash.
Note 2. The larger the error number, the older the alarm.
Note 3. The display “A--” indicates no alarm.
H Alarm History Data Clear (Fn006)
Use the alarm history data clear (Fn006) to clear all the alarm history in memory.
Note When you clear the alarm log data, the alarm history display for all alarms will change to “j-A.--.”
System Check Mode
Alarm history data clear
Alarm history data clear display
(trCLr displayed)
Alarm history data clear
operation
Flashing donE displayed
(clear completed)
Returns to trCLr
display.
(1 s later)
1 s min.
1 s min.
Operation Chapter 4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron OMNUC R88D-WT15HF and is the answer not in the manual?

Omron OMNUC R88D-WT15HF Specifications

General IconGeneral
BrandOmron
ModelOMNUC R88D-WT15HF
CategoryServo Drives
LanguageEnglish

Related product manuals