3-11
Param-
eter
No.
(Regis-
ter No.
(Hex))
MemoChanges
during
opera-
tion
Default
setting
Set-
ting
range
DescriptionName
n39
(0127)
Multi-func-
tion input 4
(Input ter-
minal S5)
19 Emergency
stop fault
(NO)
The Inverter stops ac-
cording to the setting in
n04 for interruption mode
selection with the emer-
gency stop input turned
2 to 8,
10 to
22,
34, 35
6 No
20 Emergency
stop alarm
(NO)
gency
stop
input
turned
ON.
NO: Emergency stop with
the contact closed.
NC: Emergency stop with
21 Emergency
stop fault
(NC)
gyp
the contact opened.
Fault: Fault output is ON
and reset with RESET
input. Alarm output is ON
(no reset required)
22 Emergency
stop alarm
(NC)
(
no rese
t
requ
i
re
d)
.
“STP” is displayed (lit
with fault input ON and
flashes with alarm input
ON)
34 Up or down
command
Up or down command
(set in n39 only)
By setting n39 to 34, the
set value in n38 is ig-
nored and the following
setting are forcibly made.
S4: Up command
S5: Down command
35 Self-diag-
nostic test
ON: RS-422A/485 com-
munications self-diagnos-
tic test (set in n39 only)
List of Parameters Chapter 3