EasyManua.ls Logo

Omron SYSMAC CJ1W-SCU41-V1

Omron SYSMAC CJ1W-SCU41-V1
781 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
235
Conditions Requiring Routing Tables Section 6-7
Serial-to-Serial-to-Serial Conversion
Routing tables to enable the serial communications path to be treated as a
network are optional.
Without Routing Tables
Specify the addresses as shown in the following example.
With Routing Tables
Specify the addresses as shown in the following example.
6-7-4 Explanation
To treat the serial communications path as a network, the serial port itself is
recognized as a Communications Unit and is allocated a network address.
Address Specification
Address
Contents
Example
s+1
Serial Communications Unit/Board
E.g., Unit number 2, port 1
Serial Communications Unit/Board
E.g., Unit number 0, port 1
Target: OMRON Component or Modbus Slave
PLC_1
PLC_2
CPU Unit
CPU Unit
FINS
command
sent
Remote net-
work address
Remote node
address
Remote unit
address
PLC_1 serial port
unit address
PLC_2 unit number for
Host Link + 1
PLC_2 serial port
unit address
89 hex (137 decimal)
Calculated from PLC_1 unit
number 2, port 2
80 hex (128 decimal)
Calculated from unit number
0, port 1
Serial communications
path (Host Link FINS)
(1) Network address:
To PLC_1 serial port unit
address (e.g., 89 hex)
No routing tables required to treat serial
communications path as a network
Serial communications
path (Host Link FINS)
No routing tables required to treat serial
communications path as a network
(2) Node address: PLC_2
unit numbers for Host Link
(0 to 31) + 1
(3) Unit address: To
PLC_2 serial port unit
address (e.g., 80 hex)
Serial communications path
(CompoWay/F, Modbus)
Address Contents Example
A
s+1
PLC_2 serial port unit address
Serial Communications Unit/Board
E.g., Unit number 2, port 1
Serial Communications Unit/Board
E.g., Unit number 0, port 1
Target: OMRON Component or Modbus Slave
Unit number
80 hex (128 decimal)
Calculated from unit number 0, port 1
A
CPU Unit
Address Specification
PLC_2
PLC_1
CPU Unit
FINS
command
sent
Serial communications
path (Host Link FINS)
Remote network
address
Remote node
address
Remote unit
address
PLC_2 serial communications
path network address A
PLC_2 unit number for Host
Link + 1
80 hex (128 decimal)
Calculated from unit number
0, port 1
No routing tables required to treat serial
communications path as a network
Routing tables for treating serial
communications path as a network
Serial communications
path (Host Link FINS)
(2) Node address:
PLC_2 unit numbers for
Host Link (0 to 31) + 1
(3) Unit address: To
PLC_2 serial port unit
address (e.g., 80 hex)
Network
address
Serial communica-
tions path (Compo-
Way/F, Modbus)
(1) Network address: To PLC_1 serial
communications path network address A
Serial port
Assigned to network address n
Network
Serial Communications Unit/Board
Local network table in routing tables
Unit number
(See note.)
Set correspondence
Un
Unit address U
(See note.)
Commu-
nications
Unit
Serial communica-
tions path
Ex-
pressed
as:
Network
address
Note: The unit number is set as a
CPU Bus Unit for Communica-
tions Units, but the unit ad-
dress (80 hex/81 hex + unit
number × 4 hex, as a decimal)
is set for the serial
p
ort.

Table of Contents

Related product manuals