EasyManuals Logo

Omron SYSMAC CJ1W-SCU41-V1 User Manual

Omron SYSMAC CJ1W-SCU41-V1
781 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #424 background imageLoading...
Page #424 background image
395
C-mode (Host Link) Command Master Appendix C
703 (02BF) LR AREA READ Reads the contents of the specified number of LR Area
(CS/CJ Series: CIO 1000 to CIO 1199) words beginning
with the designated word from the specified Host Link
Unit and stores starting from the specified storage word.
Ye s Ye s
704 (02C0) HR AREA READ Reads the contents of the specified number of HR Area
words beginning with the designated word from the spec-
ified Host Link Unit and stores starting from the specified
storage word.
Ye s Ye s
705 (02C1) TIMER/COUNTER
PV READ
Reads the contents of the specified number of timer/
counter PV words beginning with the designated word
from the specified Host Link Unit and stores starting from
the specified storage word.
Ye s Ye s
706 (02C2) TIMER/COUNTER
STATUS READ
Reads the contents of the specified number of timer/
counter status words beginning with the designated word
from the specified Host Link Unit and stores starting from
the specified storage word.
Ye s Ye s
707 (02C3) DM AREA READ Reads the contents of the specified number of DM Area
words beginning with the designated word from the spec-
ified Host Link Unit and stores starting from the specified
storage word.
Ye s Ye s
708 (02C4) AR AREA READ Reads the contents of the specified number of AR Area
words beginning with the designated word from the spec-
ified Host Link Unit and stores starting from the specified
storage word.
Ye s Ye s
709 (02C5) EM AREA READ Reads the contents of the specified number of EM Area
words beginning with the designated word from the spec-
ified Host Link Unit and stores starting from the specified
storage word.
Ye s Ye s
710 (02C6) CIO AREA WRITE Writes the specified write data to the specified Host Link
Unit starting from the designated CIO Area word. Writing
is done in word units.
Ye s Ye s
711 (02C7) LR AREA WRITE Writes the specified write data to the specified Host Link
Unit starting from the designated Link Area (CS/CJ
Series: CIO 1000 to CIO 1199) word. Writing is done in
word units.
Ye s Ye s
712 (02C8) HR AREA WRITE Writes the specified write data to the specified Host Link
Unit starting from the designated HR Area word. Writing
is done in word units.
Ye s Ye s
713 (02C9) TIMER/COUNTER
PV WRITE
Writes the specified write data to the specified Host Link
Unit starting from the designated timer/counter PV word.
Writing is done in word units.
Ye s Ye s
714 (02CA) DM AREA WRITE Writes the specified write data to the specified Host Link
Unit starting from the designated DM Area word. Writing
is done in word units.
Ye s Ye s
715 (02CB) AR AREA WRITE Writes the specified write data to the specified Host Link
Unit starting from the designated AR Area word. Writing
is done in word units.
Ye s Ye s
716 (02CC) EM AREA WRITE Writes the specified write data to the specified Host Link
Unit starting from the designated EM Area word. Writing
is done in word units.
Ye s Ye s
717 (02CD) STATUS READ Reads the CPU Unit’s operating conditions (status) from
the specified Host Link Unit and stores in the words start-
ing from the designated word.
Ye s Ye s
718 (02CE) STATUS CHANGE Changes the CPU Unit’s operating mode for the specified
Host Link Unit.
Ye s Ye s
Sequence
No.
Communications
sequence name
Function Ladder interface
Send word
allocation
Receive
word
allocation

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CJ1W-SCU41-V1 and is the answer not in the manual?

Omron SYSMAC CJ1W-SCU41-V1 Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CJ1W-SCU41-V1
CategoryNetwork Hardware
LanguageEnglish

Related product manuals