681
Visual Inspection System Protocol Appendix O
3. The ranges of measurement values are as follows:
For calibration OFF setting:–2147483.648 to 2147483.648
For calibration ON setting:–9999999.999 to 9999999.999
4. The priority of measurement items being output are as follows:
1Area
2 Center of gravity X
3 Center of gravity Y
4 Main axis angle
5 Edge angle
6Center X
7Center Y
8 Inclination
9 Intersecting point X
10 Intersecting point Y
5. Sequences No. 452 and No. 462 (Continuous Measurement Execution with Interrupt) are not sup-
ported by the CS1W-SCU@@(-V1) and CJ1W-SCU@@(-V1) Serial Communications Units. A protocol
syntax error will occur if an attempt is made to execute either sequence with a Serial Communications
Unit.
Do not set an EM bank as the receive storage word for interrupt notification. A protocol syntax error
will occur if an EM banks is set.
Reference Object Registration Command 1 Execution (F300)
(Sequence No. 463 (Hex 01CF))
This sequence performs a measurement for the input image and updates reference object data of the full win-
dow.
Send Data Word Allocation (3rd Operand of PMCR(260))
None.
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Reference Object Registration Command 2 Execution (F300)
(Sequence No. 464 (Hex 01D0))
This sequence performs a measurement for the input image and updates the reference object data of a desig-
nated window.
Send Data Word Allocation (3rd Operand of PMCR(260))
Receive Data Word Allocation (4th Operand of PMCR(260))
None.
Offset Contents (data format) Data
+0 Number of send data words
(4 digits Hex)
0002
+1 Window No. (1 digit BCD) 0 to 7
First word of send
data
Number of send data words
+0
+1 (Undefined) Window No.