127
RFID System
User’s Manual
SECTION 5
V680 Commands
SECTION 5
Communications
WRITE REPEAT (RP)
The WRITE REPEAT command is used to execute the most recently executed write command again.
1:1 Protocol
Note: When using the multi-access trigger communications designation (MT) for a previously exe-
cuted write command, the ID controller returns an end code of 03 after communicating with all
Tags.
Write command information is cleared at the following time.
When the ID Controller's power supply is reset.
If a WRITE REPEAT command is executed after write command information has been cleared, a command input error
will occur.
1:N Protocol
Note: When using the multi-access trigger communications designation (MT) for a previously
executed write command, the ID controller returns an end code of 03 after communicating with
all Tags.
Write command information is cleared at the following time.
When the ID Controller's power supply is reset.
If a WRITE REPEAT command is executed after write command information has been cleared, a command input error
will occur.
Command code The command code is the same as the last write command that was executed.
UID A unique identifier used to identify Tags.
Added only for multi-access communications designations (MT/MR) for a previously executed
write command.
Command code The command code is the same as the last write command that was executed.
UID A unique identifier used to identify Tags.
Added only for multi-access communications designations (MT/MR) for a previously executed
write command.
Command
RP
2
2
* CR
Command
code
Terminator
Response
Command
code
Terminator
End code
Antenna
desig-
nation
Resend flag
××
00
22
2
* CR
0×
11
××
UID
××
0 or 16
...
Command
RP
2
2
* CR
2
FCS
@
2
0
11
Command
code
Terminator
Controller No.
×
××
×
Response
Command
code
Terminator
End code
Antenna
desig-
nation
Resend flag
Controller No.
××
00
22
2
* CR
0×
11
@
2
×
×
0
11
2
××
FCS
××
UID
××
0 or 16
...

Other manuals for Omron V680-CA5D01-V2