SECTION 4
Functions
Noise Monitor Function
When executing commands for Tag communications, the maximum value of the noise level can be
attached to the response data to constantly monitor noise conditions.
The noise monitor function cannot be used when the V680-H01 Antenna is connected.
To use the noise monitor function it must be enabled using the PARAMETER SET (SP) command.
p. 147
Response Examples
RD 00 1 0
......
[01] * CR
Maximum noise level ("01" to "99")
RD 00 1 0
......
* CR
Read data
● Noise Monitor Function Enabled
● Noise Monitor Function Disabled
Antenna channel ("1": channel 1, "2": channel 2)
End code
Resend Flag (Always "0".)
Read data
Antenna channel ("1": channel 1, "2": channel 2)
End code
Resend Flag (Always "0".)