EasyManuals Logo

Omron V680-CA5D01-V2 User Manual

Omron V680-CA5D01-V2
274 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #166 background imageLoading...
Page #166 background image
163
RFID System
User’s Manual
SECTION 5
V680 Commands
SECTION 5
Communications
1:N Protocol
Process designation Specifies the process to execute.
“00”: Read error information
“01”: Clear error information
New error log information Up to 30 records of error log information will be returned.
Error log information is returned in chronological order with the newest records first. Each record
is five characters long.
Command
CF
× 0
21
2
* CR
1
@
2
0
11
FCS
2
Command
code
Terminator
Controller No.
×
Process
desig-
nation
Fixed
value
×
×
×
Response
CF
22
2
* CR
0
1
0
1
...
New error log information
n
@
2
0
11
FCS
2
Command
code
Terminator
End code
Resend
flag
Controller No.
Fixed
value
××
×
×
××
×
×
×
×
RD 1 70 ;
Generated end code
Error command
Head No. with error (for communications with Data Carriers only)
A space will be output for when the error is not a communications error.

Other manuals for Omron V680-CA5D01-V2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V680-CA5D01-V2 and is the answer not in the manual?

Omron V680-CA5D01-V2 Specifications

General IconGeneral
BrandOmron
ModelV680-CA5D01-V2
CategoryController
LanguageEnglish

Related product manuals