177
RFID System
User’s Manual
SECTION 5
V600 Commands
SECTION 5
Communications
Host Commands
The following commands are used to control the ID Controller.
FCS Calculation Example
Reading 5 Bytes Started from Address 0010H
Command
code
Name Description Page
TS TEST Checks the communications conditions between the ID Controller and host
device. The data sent by the host device is returned by the ID Controller without
modification.
p. 223
CC CONTROLLER
CONTROL
Controls ID Controller I/O. p. 224
CF READ ERROR
INFORMATION
Reads the error log. p. 226
TR COMMUNICA-
TIONS SET
Sets serial communications parameters for communicating with the host device. p. 228
SP PARAMETER SET Sets, reads, or initializes ID Controller parameters. p. 230
0100
0011
0011
0101
0100
0100
0011
0011
0011
0011
0011
0011
0011
0000
0000
0010
0010
0100
1000
0001
0000
0000
0001
0000
0000
0101
XOR
XOR
XOR
XOR
XOR
XOR
@
0
2
R
D
H
1
0
0
1
0
0
5
0010 1001
40
30
32
52
44
48
31
30
30
31
30
30
35
XOR
XOR
XOR
XOR
XOR
XOR
00
01
H
10
29
5
FCS
*
CR
RD
2
@0
FCS data: 29
Converted to
hexadecimal
Exclusive OR
Converted to
binary
Converted to
ASCII
ASCII (hex)
Original data
Terminator
Command
codeController No.
Data
FCS calculation range
Binary

Other manuals for Omron V680-CA5D01-V2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V680-CA5D01-V2 and is the answer not in the manual?

Omron V680-CA5D01-V2 Specifications

General IconGeneral
BrandOmron
ModelV680-CA5D01-V2
CategoryController
LanguageEnglish

Related product manuals