208
SECTION 5
V600 Commands
RFID System
User’s Manual
SECTION 5
Communications
Query/cancel designation Specifies querying or canceling polling auto processing.
“C”: Processing results query
“E”: Processing results cancel
Antenna designation Specifies the Antenna for querying or canceling.
“1”: Antenna 1
“2”: Antenna 2
End code Indicates the execution result for the command.
“00”: Normal end
“74”: No Tag has approached when polling auto processing results were requested.
“75”: No Tag has approached when polling auto processing was cancelled.
“76”: Communications processing was in progress or completed when polling auto processing
was cancelled.
Refer to List of End Codes for information on other end codes.
p. 235
Read data The data that was read according to the command that was executed.
Command
code
PR
C/E 1/2
2
2
* CR
Terminator
Query/cancel designation
Antenna designation
11
Subcommand
Subcommand Response
×
Command
code
PR
...
×
00
××
22 n
2
* CR
TerminatorRead dataEnd code