219
RFID System
User’s Manual
SECTION 5
V600 Commands
SECTION 5
Communications
WRITE REPEAT (RP)
The WRITE REPEAT command is used to execute the most recently executed write command again.
1:1 Protocol
Write command information is cleared at the following time.
When the ID Controller's power supply is reset.
If a WRITE REPEAT command is executed after write command information has been cleared, a command input error
will occur.
Command code The command code is the same as the last write command that was executed.
End code Indicates the execution result for the command.
“00” indicates a normal end.
Refer to List of End Codes for information on other end codes.
p. 235
Command
RP
2
2
* CR
Command
code
Terminator
Response
××
00
22
2
* CR
Command
code
Terminator
End code