231
RFID System
User’s Manual
SECTION 5
V600 Commands
SECTION 5
Communications
Parameter J is valid only for version 2.1 or newer. For details on Checking the Version, refer to page 17.
Parameter data
(when there are changes)
“C” Specify 4 decimal digits. “0000” to “9999” (ms)
“0000”: Infinite, Default value: “0500” (ms)
“D” Specify 4 hexadecimal digits. ”0001” to “0800” (bytes)
Default value: “0001” (bytes)
“E” “0”: Noise monitor function OFF (default value)
“1”: Noise monitor function ON
“G” Specify 4 decimal digits. “0001” to “0100” (times)
Default value: “0010” (times)
“H” “0”: Write protection OFF (default value)
“1”: Write protection ON
“J” “0”: V680 write protection (default value)
“1”: V600 write protection
Note 1: Parameters 1, 2, 9, B, and H are valid only when internal settings are enabled (i.e., when pin 1 on SW3 is ON).
Note 2: Parameter J is valid only for version 2.1 or newer.
Note 3: The data number of the parameter data is the number specified for the lower digit of the process code.
The settable values for the data number are the same as for the parameter specified by the lower digit of the process code.
End code Indicates the execution result for the command.
“00” indicates a normal end.
Refer to List of End Codes for information on other end codes.
p. 235
Parameter data Attached only when parameter data is being obtained.
Response
S
00
22
2
* CR
1 to 4
P
Command
code
Terminator
End code
×
Parameter data
×
××