89
RFID System
User’s Manual
SECTION 4
Write Protection
SECTION 4
Functions
Start Address Higher Than End Address
The memory area between the start address and the last ID Tag address, as well as the area between
0006H and the end address will be write-protected.
The write protection setting area of the ID Tag cannot be write-protected.
Addresses 0000
H and 0001H are always write-protected, regardless of the setting of the write protection function.
Address Bit Upper digits Lower digits
0002
H
10000001
81
0003
H
00100000
20
0004
H
00000000
00
0005
H
00010101
15
Address
0015
H
7FFF
H
Write-
protected
area
0120
H
Write-
protected
area
0000
H
0006
H
Last address
End address