Bare Wiring
Two Hot Wires & Ground
Licensed Electrician
REQUIRED
Bare Wiring
Two Hot Wires & Ground
Licensed Electrician
REQUIRED
6 Oneida Air Systems
Supercell/Supercell Turbo System Specications
OPERATION
Maximum Suction Rating 97.8" WC
MOTOR AND ELECTRICAL
Motor Type 3x 1300W Modular Motors / 4x 1300W Modular Motors
Horsepower 5HP Total / 6.7 HP Total
Motor Speed 48,880 RPM
Phase 1-Phase
Voltage 208-230V
Cycle 60Hz
Listed FLA 18A / 22A
On/O Switch Magnetic Starter with On-O Switch and RF Remote
Power Cord Length 10 feet
Power Connector NEMA 6-20 / Bare Wiring
Recommended Circuit Size 20A / 30A
Recommended Circuit Type HACR
Sound Emission 80 dBA @ 10 ft / 85 dBA @ 10 ft
CARTRIDGE FILTER
Filter Media Type HEPA Certied
Filter Eciency 99.97% @ 0.3 microns
Filter Surface Area 40 sq ft
SYSTEM DIMENSIONS AND CONSTRUCTION
Primary Build Materials Cold Rolled Steel, Static Dissipative Polyethylene
Inlet 4" O.D.
Discharge to Drum 5" O.D.
Overall Height 30 Gallon: 79-3/16"; 2,011 mm without Universal Drum Dolly
35 Gallon: 72-7/8"; 2,108 mm without Universal Drum Dolly
55 Gallon: 84-1/4"; 2,140 mm without Universal Drum Dolly
Overall Weight 30 Gallon: 95 lbs
35 Gallon: 95 lbs
55 Gallon: 102 lbs
e Supercell requires a 20 Amp
outlet receptacle to be installed by a
licensed electrician.
e Supercell Turbo requires that
it be installed to a 30 Amp breaker
(minimum) by a licensed electrician.