Oneida Air Systems, Inc.28
Troubleshooting
If you continue to experience difficulty with your dust collector, call Oneida Air Systems Customer Service
Department at 1-866-387-8822 or email support@oneida-air.com.
PROBLEM CAUSE SOLUTION
Motor Overheating/System
Tripping
(The motor’s overload
will trip if the motor is
overheating)
Motor not properly wired
1. Check wire connections.
2. Check breaker box to make sure power supply is correct for motor.
3. Check overload setting in starter.
Poor dust pick-up at Tools System and ductwork
connections
1. Check length of duct runs, duct diameters, and hood design compared to ductwork
design guidance.
2. Make sure all connections to the system are sealed. Large air losses will occur even
through small cracks in the ex hose or ductwork. Use silicone, duct tape or duct
mastic compound as a sealant.
3. Make sure everything is connected.
4. Check for air leaks between collector and dust drum.
5. Be sure that your lter is clean.
One of the three motors may
have reached its end of life
1. Replacements can be found in the Recommended Accessories section.
2. Use the QR Code shown to download our instructions for the Testing and
Replacement of the Motor Maintenance Kit.